Open heat exchanger for improved energy efficiency in the heating of hot spas

Skoða venjulega færslu

dc.contributor Jarðhitaskóli Háskóla Sameinuðu þjóðanna is
dc.contributor.author Jalili-Nasrabadi, Saeid is
dc.date.accessioned 2017-06-01T14:26:24Z
dc.date.available 2017-06-01T14:26:24Z
dc.date.issued 2008-12
dc.identifier.isbn 9789979682509 (ób.)
dc.identifier.issn 1670-7427
dc.identifier.uri http://hdl.handle.net/10802/12775
dc.description Lokaritgerð (MS) við Háskóla Íslands is
dc.description Myndefni: myndir, línurit, töflur is
dc.description.abstract Hot spas and Jacuzzis are popular in Iceland due to the abundance of reasonably prized geothermal heat available. However the water from the district heating system is too warm to be admitted directly into the spa. For safety reasons the water is mixed with cold water, from 75 down to 50ºC, which leads to wasting a large quantity of heat. Therefore a design was suggested that enables the feeding of geothermal water directly into the pot, omitting the step of mixing it with cold water. The idea is to employ an open heat exchanger that transfers much heat from the geothermal water to the bulk water in the spa, before letting it mix with the spa water. A case study was done for one particular spa. Heat load was calculated and measured when the spa was in use, and when it was unused. A design is suggested employing a circular double-plate which is to be placed at bottom of pot. This unit will function as an open heat exchanger feeding district heating water into the pot. Free convection takes place at the up side of the upper plate and forced convection below the upper plate. Heat transfer coefficient for both was calculated. Temperature field in the pool before and after implementation of the open heat exchanger was measured at different points using thermocouples. The measured temperatures were compared to thermal and fluid-dynamic simulation of the temperature and flow fields obtaining good accordance. Results are reasonable and promising for a good design that may considerably reduce the energy expenses for a continuously heated geothermal spa.... is
dc.format.extent viii, 56 s. is
dc.language.iso en
dc.publisher United Nations University is
dc.publisher Orkustofnun is
dc.relation.ispartofseries United Nations University., UNU Geothermal Training Programme, Iceland. Report ; 2008:4
dc.relation.uri http://www.os.is/gogn/unu-gtp-report/UNU-GTP-2008-04.pdf
dc.subject Meistaraprófsritgerðir is
dc.subject Jarðhiti is
dc.subject Jarðhitarannsóknir is
dc.subject Sundlaugar is
dc.subject Vatnsveitur is
dc.subject Jarðhitasvæði is
dc.subject Jarðefnafræði is
dc.subject Jarðboranir is
dc.subject Hitaveita is
dc.title Open heat exchanger for improved energy efficiency in the heating of hot spas en
dc.type Bók is
dc.identifier.gegnir 991007674539706886


Skrár

Skrá Stærð Skráartegund Skoða Lýsing
UNU-GTP-2008-04.pdf 3.572Mb PDF Skoða/Opna Heildartexti