Borehole geology and hydrothermal alteration of well SV-5A, San Vicente geothermal field, El Salvador, C.A

Skoða venjulega færslu

dc.contributor Jarðhitaskóli Háskóla Sameinuðu þjóðanna is
dc.contributor.author Pichardo López, Claudia Mercedes is
dc.date.accessioned 2014-10-07T11:39:38Z
dc.date.available 2014-10-07T11:39:38Z
dc.date.issued 2014
dc.identifier.issn 1670-7427
dc.identifier.uri http://hdl.handle.net/10802/7681
dc.description Í: Geothermal training in Iceland 2013, s. 691-716 is
dc.description Myndefni: kort, gröf, töflur is
dc.description.abstract Well SV-5A is an exploration well located in El Salvador in the San Vicente geothermal field. It is a directional well, drilled to a depth of 1798.5 m. The drill cuttings of the well were analysed through a binocular microscope and through a petrographic microscope in thin sections. The lithology of Well SV-5A consists of andesite lava flows, basalt-andesite, dacite and three different types of tuffs: crystal tuff, lithic tuff and crystal-lithic tuff. The alteration minerals show that temperature increases with depth. Mineralogical assemblages reflect five zones of alteration: a smectite-zeolite zone at 386-750 m, a mixed layer clay zone at 750-920 m, a chlorite zone at 920-1200 m, a chlorite-epidote zone at 1200-1242 m, and an epidoteactinolite zone at 1500-1798.5 m. Four aquifers were identified in the production section of the well, based on the temperature profiles and circulation losses during drilling. When the first appearance of alteration minerals and the results of the analysis of fluid inclusions were compared, equilibrium was observed, reflecting a temperature of 280°C at 1500 m depth. The formation temperature estimated at that same depth in the well is 240°C. By comparing the formation temperature with fluid inclusions and the alteration mineralogy, a cooling of about 40°C has occurred in the geothermal system. According to the calculated Horner temperature, the well was still in a thermal recovery process during the last temperature log, which showed an increase of 5°C, which means that the formation temperature of the well could possibly reach 245°C. is
dc.format.extent 26 s. is
dc.language.iso en
dc.publisher United Nations University is
dc.publisher Orkustofnun is
dc.relation.ispartofseries United Nations University., UNU Geothermal Training Programme, Iceland. Report ; 2013 : 29
dc.relation.uri http://os.is/gogn/unu-gtp-report/UNU-GTP-2013-29.pdf
dc.subject Jarðhiti is
dc.subject Borholur is
dc.subject Jarðfræði is
dc.subject El Salvador is
dc.title Borehole geology and hydrothermal alteration of well SV-5A, San Vicente geothermal field, El Salvador, C.A en