Titill:
|
Reservoir assessment of the southeast sector of the Kamojang geothermal field, IndonesiaReservoir assessment of the southeast sector of the Kamojang geothermal field, Indonesia |
Höfundur:
|
Sasradipoera, Doddy Satyajit
;
Jarðhitaskóli Háskóla Sameinuðu þjóðanna
|
URI:
|
http://hdl.handle.net/10802/23291
|
Útgefandi:
|
United Nations University; Orkustofnun
|
Útgáfa:
|
1995 |
Ritröð:
|
United Nations University., UNU Geothermal Training Programme, Iceland. Report ; 1995:12 |
Efnisorð:
|
Jarðhiti; Jarðhitarannsóknir; Jarðhitanýting; Filippseyjar
|
ISSN:
|
1670-7427 |
Tungumál:
|
Enska
|
Tengd vefsíðuslóð:
|
http://www.os.is/gogn/unu-gtp-report/UNU-GTP-1995-12.pdf
|
Tegund:
|
Bók |
Gegnir ID:
|
991010423669706886
|
Athugasemdir:
|
Myndefni: kort, línurit, töflur. |
Útdráttur:
|
A general description is given on the southeast sector of the Kamojang geothermal field. It is assumed that there is a low-permeability barrier separating the sector from the main production field. Evaluation of formation temperatures and pressures is carried out from 175 downhole measurements. A conceptual reservoir model is presented, suggesting a vapour dominated reservoir of 240-246°C initial temperature and 35-37 bars initial pressure. The reservoir is around 1 km thick and overlain by 500-1000 m thick liquid saturated caprock. The southeast sector of the Kamojang field appears to be 2-4°C hotter than the main wellfield, suggesting either the existence of an upflow zone or a low permeability volume. Volumetric assessment for the southeast sector of Kamojang suggests a power potential of 9.5 MWe per km2 of the wellfield. Estimating the reservoir area to be 1.5-2.5 km 2 gives 14-24 MWe in total. On the other hand, by using the Monte Carlo statistical approach, a 15-30 MWe reserve estimate is obtained for the wellfield. |