#

The role of well testing in geothermal resource assessment

Skoða venjulega færslu

dc.contributor Jarðhitaskóli Háskóla Sameinuðu þjóðanna is
dc.contributor.author Rutagarama, Uwera is
dc.date.accessioned 2017-06-01T14:27:20Z
dc.date.available 2017-06-01T14:27:20Z
dc.date.issued 2012
dc.identifier.isbn 9789979683216 (ób.)
dc.identifier.issn 1670-7427
dc.identifier.uri http://hdl.handle.net/10802/12777
dc.description MSc thesis is
dc.description Lokaritgerð (MSc) frá Háskóla Íslands is
dc.description Myndefni: gröf, töflur is
dc.description.abstract In this thesis, different approaches and methods for analysing well test data to estimate the capacity of a geothermal field are evaluated. The thesis lays emphasis on well completion and flow tests data, and uses the Reykjanes geothermal field in southwest Iceland as an example for the application of the selected methods. Analyses of data from step-rate injection tests, temperature and pressure profiles as well as discharge tests conducted in the Reykjanes geothermal field are presented. Six wells, RN-12, RN-13b, RN-17b, RN-18, RN-23 and RN-29 were selected for the study. The computer numerical software, Well Tester, is used for the step-rate injection test analysis. Temperature and pressure profiles are analysed to estimate the formation temperature and the initial reservoir pressure. Flow characteristics are evaluated from the lip pressure method and the steam-water separator method, respectively. The wellbore simulator, HOLA, is used to evaluate the generating capacity and productivity indices of individual wells. The injectivity and productivity indices are compared with results from other similar high temperature geothermal fields. The volumetric method based on well test data is applied to predict the electrical generation capacity of the Reykjanes geothermal system. is
dc.description.abstract The estimated values of permeability-thickness from the injection tests range from 1 Dm to 30 Dm, whereas the storativity ranges from 5•10-8 m/Pa to 2•10-7 m/Pa. The reservoir temperature estimate is between 280 oC and 340 oC. The average capacity for producing electricity is estimated around 10 MWe per well. The resource assessment is performed for two cases. Case I considers the surface alteration area of the Reykjanes field of 2 km2 while case II considers the low resistivity sheet at 1000 m depth b.s.l. of an area of 11 km2. The Monte Carlo simulation for case I predicts with 90% confidence interval a generating capacity between 34 MWe and 102 MWe for a recoverable heat, with a most likely value of 65 MWe and between 20 MWe and 61 MWe with a most likely value of 39 MWe for 30 years and 50 years, respectively. For case II, the simulation predicts with 90 % confidence interval a generating capacity between 38 MWe and 290 MWe with a most likely value of 132 MWe and between 23 MWe and 174 MWe with a most likely value of 79 MWe for 30 years and 50 years, respectively. is
dc.format.extent viii, 71 s. is
dc.language.iso en
dc.publisher United Nations University is
dc.publisher Orkustofnun is
dc.relation.ispartofseries United Nations University., UNU Geothermal Training Programme, Iceland. Report ; 2012:02
dc.relation.uri http://www.os.is/gogn/unu-gtp-report/UNU-GTP-2012-02.pdf
dc.subject Meistaraprófsritgerðir is
dc.subject Borholur is
dc.subject Borholumælingar is
dc.title The role of well testing in geothermal resource assessment en
dc.type Bók is
dc.identifier.gegnir 991002470569706886


Skrár

Skrá Stærð Skráartegund Skoða Lýsing
UNU-GTP-2012-02.pdf 5.182Mb PDF Skoða/Opna Heildartexti

Þetta verk birtist í eftirfarandi flokki:

Skoða venjulega færslu

Leita


Fletta